Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (2024)

by Tim David

FacebookXReddit

If you are dealing with a Sw Open message on your Raypak heater, I have a solution for you! Over my years of fixing Raypak heaters, the Sw is one of the more common issues I get calls on. A Raypak heater is typically equipped with a pressure switch that only allows the heater to fire up when there is sufficient water flow.

Q: I am trying to turn on my Raypak pool heater for the season and getting a RollOut Sw Open error on the monitor. How can I fix this? – Ron Wells

Problem: Your pool heater might show an error indicating a problem with the rollout switch. This switch is a critical safety feature designed to prevent the heater from overheating or catching fire. It’s a common issue that can cause your pool heater to malfunction.

Solution: (From Tim at Airlucent) The issue was successfully fixed by identifying and replacing a faulty rollout switch in the Raypak natural gas pool heater. I first confirmed the error message on the heater’s display, which indicated a problem with the rollout switch. This switch is a crucial safety component that prevents overheating and potential fire hazards. I tested the switch for continuity using a voltmeter and found it was burnt out, necessitating a replacement. Before installing the new switch, I inspected the exhaust and combustion chamber for any blockages or debris, as these could cause similar issues. After replacing the switch and ensuring there were no other signs of damage or malfunction, the heater resumed normal operation. It’s important to note that while replacing the rollout switch is a straightforward task, it’s essential to prioritize safety and seek professional assistance if unsure about any steps in the process.

It must be noted, however, that the pressure switch is only suitable for determining water pressure in a heater installation where the inlet/outlet water piping is 150 mm below or above the pool level. Otherwise, it doesn’t work and could be the reason for the SW open error.

Or if you need a new Raypak heater, check these new models:

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (3)

Raypak 266,000 BTU Digital Electronic Ignition Natural Gas Pool Heater

  • Built to withstand various weather conditions, perfect solution for environments requiring efficiency, convenience and versatility.
  • Intermittent spark ignition pilot safety controls. Pilot only comes on when there is a call for heat.

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (4)

Raypak 105,000 BTU Swimming Pool and Spa Heater – Natural Gas

  • Designed for easy installation on above ground pools, smaller in-ground pools, and spas
  • Standard 120v 3-prong power cord or can be easily converted to 220v

Step-By-Step Instructions for Fixing the Sw Error Code

If you’re encountering only a Sw Open error with your pool heater, it’s likely due to a restriction in water flow. Here’s a detailed guide to help you troubleshoot and fix this issue:

  1. Inspect Shut-off Valves: Begin by checking the plumbing around your pool heater. Look for any shut-off valves that might be closed. Ensure all water valves are open and positioned correctly to allow normal water flow to the pool.
  2. Check Inlet/Outlet Bypass Valves: Verify if any bypass valves are open. If you find them open, close them. Open bypass valves can restrict water flow to the heater, leading to the SW open Code.
  3. Clear Obstructions in Intake: Investigate the heater’s intake for any obstructions. Removing these blockages should get your heater working again.
  4. Clean Water Filters: Ensure that both the pump basket and the skimmer basket are clean and free from debris, like leaves. Clogged filters are a common cause of restricted water flow. After cleaning, check if the heater functions properly. If it does, regular filter maintenance might be needed. Depending on your model, clean the cartridges or backwash the filter.
  5. Test Pressure Switch: Use a multimeter to test the ends of the pressure switch for continuity. Also, check for any loose wires. If there’s no voltage, the pressure switch might be defective and may need replacement.
  6. Adjust the Pressure Switch: Incorrectly set pressure switches can trigger the SW error. Refer to your heater’s manual for guidance on adjusting the pressure switch.
  7. Secure Loose Wires on Pressure Switch: Check for any loose wires on the pressure switch and securely reattach them.
  8. Check Recirculation Pump: Ensure that the recirculation pump is operational and not set too low. A malfunctioning pump can lead to insufficient water flow.

Note: Even if water intake appears normal in the pool, there could still be a flow restriction significant enough to trigger the SW error. Regular maintenance and checks are key to preventing such issues.

Final Thought

We have seen that the SW open message on your Raypak heater is commonly triggered by issues relating to the pressure switch. That is a problematic pressure switch or an insufficient flow of water into the heater.

That said, there are a few things you can do to keep your pool heater running in great condition. These include:

1. Monitoring chlorine and PH levels of your pool water regularly (depending on what is recommended in the user manual.)

2. Do not run your heater if the water balance is out of the parameters specified by your manufacturer.

Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page.

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (5)

Tim David

HVAC tech with over 30 years of experience. Retired and doing repair work on the side around Madison County, AL.

FacebookXReddit

Raypak Pool Heater RollOut Sw OPEN Code: (Causes & Fixes) - Airlucent (2024)

FAQs

What causes flame rollout on a pool heater? ›

You can try to clean the heat exchange by inserting something into the tubes. However if the obstruction is more than a spider web you will have to remove it to clean it. The roll out is a safety to advise you that either your flue passage is restricted or your gas pressure is extremely hi.

What does open water sensor mean on pool heater? ›

As for your issue. (open water temp sensor) That means the control board can no longer read the temperature of the incoming water.

Why is my Raypak pool heater not kicking on? ›

Check the Power: If your Raypak pool heater isn't working at all, the problem could be something as simple as a lack of power. Go make sure there aren't any tripped circuit breakers in the fuse box, then check that the unit's time clock is set to the “On” position.

What causes flame rollout to open? ›

How Does It Happen? Flame rollouts in gas furnaces and boilers are caused by a high concentration of combustion gases inside the combustion chamber. Normally, these inflammable gases are exhausted from the furnace through the flue passageways in the heat exchanger, then up the vent to the exterior of the home.

What is a rollout switch on a heater? ›

Your furnace has a safety device that is designed to detect flame. rollouts. It's called a flame rollout switch, and it cuts off the. gas supply to your furnace when it detects higher temperatures than normal. immediately outside the combustion chamber.

What causes ignition lockout on pool heater? ›

Filters and strainers that are clogged—temperature monitoring requires unrestricted flow. Setting the pool heater to over 105°F is a simple technique to generate temperature excesses and lockouts. Solar heat gain—when the pool is not in use, cover it to keep the sun's heat from altering the water temperature.

What is open outlet water heater? ›

For open-outlet (low-pressure) storage type electric water heaters, they are designed to supply only one serving point and the outlet is controlled by a special water mixer which maintains a vented passage for the air inside the tank to the atmosphere.

What does water flow lockout mean on pool heater? ›

This is an Electric pool heater(heat pump) to me it sounds like either the unit isn't getting or seeing enough water flow. The pools filters might need to be cleaned or replaced, or the flow switch in the heater needs to be replaced or is blocked..

What does SPK mean on a Raypak pool heater? ›

What does that mean? SPK means that the heaters safeties are all closed. You have to change the set point above the water temperature in the pool or spa so the heater will light the pilot and prove that it is lit.

References

Top Articles
Latest Posts
Article information

Author: Roderick King

Last Updated:

Views: 6136

Rating: 4 / 5 (71 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Roderick King

Birthday: 1997-10-09

Address: 3782 Madge Knoll, East Dudley, MA 63913

Phone: +2521695290067

Job: Customer Sales Coordinator

Hobby: Gunsmithing, Embroidery, Parkour, Kitesurfing, Rock climbing, Sand art, Beekeeping

Introduction: My name is Roderick King, I am a cute, splendid, excited, perfect, gentle, funny, vivacious person who loves writing and wants to share my knowledge and understanding with you.